Suppr超能文献

智能手表评估老年人身体活动的可用性和准确性:观察性研究。

Usability and Accuracy of a Smartwatch for the Assessment of Physical Activity in the Elderly Population: Observational Study.

机构信息

Unit of Biostatistics, Epidemiology and Public Health, Department of Cardiac-Thoracic-Vascular Sciences and Public Health, University of Padova, Padova, Italy.

Department of Biology, University of Padova, Padova, Italy.

出版信息

JMIR Mhealth Uhealth. 2021 May 5;9(5):e20966. doi: 10.2196/20966.

Abstract

BACKGROUND

Regular physical activity (PA) contributes to the primary and secondary prevention of several chronic diseases and reduces the risk of premature death. Physical inactivity is a modifiable risk factor for cardiovascular disease and a variety of chronic disorders such as diabetes, obesity, hypertension, bone and joint diseases (eg, osteoporosis and osteoarthritis), depression, and colon and breast cancer. Population aging and the related increase in chronic diseases have a major impact on the health care systems of most Western countries and will produce an even more significant effect in the future. Monitoring PA is a valuable method of determining whether people are performing enough PA so as to prevent chronic diseases or are showing early symptoms of those diseases.

OBJECTIVE

The aim of this study was to estimate the accuracy of wearable devices in quantifying the PA of elderly people in a real-life setting.

METHODS

Participants aged 70 to 90 years with the ability to walk safely without any walking aid for at least 300 meters, who had no walking disabilities or episodes of falling while walking in the last 12 months, were asked to walk 150 meters at their preferred pace wearing a vívoactive HR device (Garmin Ltd) and actual steps were monitored and tallied by a researcher using a hand-tally counter to assess the performance of the device at a natural speed. A Bland-Altman plot was used to analyze the difference between manually counted steps and wearable device-measured steps. The intraclass correlation coefficient (ICC) was computed (with a 95% confidence interval) between step measurements. The generalized linear mixed-model (GLMM) ICCs were estimated, providing a random effect term (random intercept) for the individual measurements (gold standard and device). Both adjusted and conditional ICCs were computed for the GLMM models considering separately the effect of age, sex, BMI, and obesity. Analyses were performed using R software (R Foundation for Statistical Computing) with the rms package.

RESULTS

A total of 23 females and 26 males were enrolled in the study. The median age of the participants was 75 years. The Bland-Altman plot revealed that, excluding one observation, all differences across measurements were in the confidence bounds, demonstrating the substantial agreement between the step count measurements. The results were confirmed by an ICC equal to .98 (.96-.99), demonstrating excellent agreement between the two sets of measurements.

CONCLUSIONS

The level of accuracy of wearable devices in quantifying the PA of elderly people in a real-life setting that was found in this study supports the idea of considering wrist-wearable nonmedical devices (widely available in nonspecialized stores) as reliable tools. Both health care professionals and informal caregivers could monitor the level of PA of their patients.

摘要

背景

有规律的身体活动(PA)有助于慢性病的一级和二级预防,并降低早逝的风险。身体活动不足是心血管疾病和多种慢性疾病的可改变危险因素,如糖尿病、肥胖症、高血压、骨骼和关节疾病(如骨质疏松症和骨关节炎)、抑郁症以及结肠癌和乳腺癌。人口老龄化以及与之相关的慢性病增加对大多数西方国家的医疗保健系统产生了重大影响,并将在未来产生更重大的影响。监测身体活动是确定人们是否进行了足够的身体活动以预防慢性病或是否出现这些疾病早期症状的一种有价值的方法。

目的

本研究旨在评估可穿戴设备在真实环境中量化老年人身体活动的准确性。

方法

邀请年龄在 70 至 90 岁之间、能够安全行走且无需任何助行器行走至少 300 米、在过去 12 个月内无行走障碍或行走时跌倒发作的参与者,以他们喜欢的速度穿着 vívoactive HR 设备(佳明有限公司)行走 150 米,由一名研究人员使用手动计数器来监测和记录实际步数,以评估设备在自然速度下的性能。使用 Bland-Altman 图分析手动计数的步数与可穿戴设备测量的步数之间的差异。计算了(95%置信区间内)步测之间的组内相关系数(ICC)。计算广义线性混合模型(GLMM)的 ICC,为个体测量值(金标准和设备)提供个体测量值的随机效应项(随机截距)。对于 GLMM 模型,分别考虑年龄、性别、BMI 和肥胖的影响,计算了调整和条件 ICC。使用 R 软件(R 基金会统计计算)和 rms 包进行分析。

结果

共有 23 名女性和 26 名男性参加了这项研究。参与者的中位年龄为 75 岁。Bland-Altman 图显示,除了一个观察值外,所有测量值之间的差异均在置信区间内,表明步数测量值之间存在显著一致性。ICC 等于.98(.96-.99),这一结果证实了两种测量方法之间存在极好的一致性。

结论

本研究发现,可穿戴设备在真实环境中量化老年人身体活动的准确性水平支持将腕戴非医疗设备(在非专业商店广泛可用)视为可靠工具的观点。医疗保健专业人员和非正式护理人员都可以监测其患者的身体活动水平。