Hsu Kuei-Ling, Balhaddad Abdulrahman A, Martini Garcia Isadora, Collares Fabrício Mezzomo, Dhar Vineet, DePaola Louis, Melo Mary Anne
University of Maryland School of Dentistry, Baltimore, MD 21201, USA.
Department of Orthodontics and Pediatric Dentistry, University of Maryland School of Dentistry, Baltimore, MD 21201, USA.
Saudi Dent J. 2021 Nov;33(7):453-461. doi: 10.1016/j.sdentj.2020.12.001. Epub 2020 Dec 10.
This study aimed to investigate the dimensional stability of irreversible hydrocolloid and polyvinylsiloxane (P.V.S.) impressions after exposure to four commercial disinfectants using cone-beam computed tomography (CBCT).
Two different impression materials were tested: irreversible hydrocolloid and P.V.S. Four disinfection solutions were applied: BirexSE, Opti-Cide3, COEfect MinuteSpray, and CaviCide Spray. Distilled water was used as a control group. Each solution remained in contact with the impression for 5 min. Additional contact time of 5 min compromises time for scanning. The materials were evaluated for dimensional stability after the impression of a maxillary complete edentulous template via CBCT before and after being in contact with the disinfectant agents. Measurements were assessed on the digital models from A-B, B-C, and C-A points. Paired analyses (Wilcoxon Signed Rank test or paired Student's -test) were used to analyze each measurement before and after the contact with the disinfectant agents. The variance for each measurement was also analyzed via a one-way analysis of variance or Kruskal-Wallis.
Overall, there were no statistical differences among the points measurements in the irreversible hydrocolloid or P.V.S. between initial and final assessments (p > 0.05). The used disinfectant agents in this study did not influence each measurement's variation on irreversible hydrocolloid or P.V.S. (p > 0.05). All agents showed an effect on the dimensional stability of both impression materials. The differences in the three dimensions ranged between 0.34 and 1.54%.
Within 10 min of removing the impression from the master cast, is study's findings indicated that the four commercially available disinfectants did not influence the dimensional stability of irreversible hydrocolloid or P.V.S. Further studies should be performed to elucidate the antimicrobial effect of these solutions applied as a spray on the surface of irreversible hydrocolloid and P.V.S. impressions.
本研究旨在使用锥形束计算机断层扫描(CBCT),调查不可逆水胶体和聚乙烯基硅氧烷(P.V.S.)印模在接触四种商用消毒剂后的尺寸稳定性。
测试了两种不同的印模材料:不可逆水胶体和P.V.S.。应用了四种消毒溶液:BirexSE、Opti-Cide3、COEfect MinuteSpray和CaviCide Spray。蒸馏水用作对照组。每种溶液与印模接触5分钟。额外5分钟的接触时间会影响扫描时间。在接触消毒剂前后,通过CBCT对全口上颌无牙模板印模后的材料进行尺寸稳定性评估。在数字模型上从A - B、B - C和C - A点进行测量。使用配对分析(Wilcoxon符号秩检验或配对学生t检验)分析接触消毒剂前后的每次测量。还通过单因素方差分析或Kruskal - Wallis分析每次测量的方差。
总体而言,不可逆水胶体或P.V.S.在初始和最终评估之间的各点测量值无统计学差异(p > 0.05)。本研究中使用的消毒剂对不可逆水胶体或P.V.S.的每次测量变化均无影响(p > 0.05)。所有试剂均对两种印模材料的尺寸稳定性有影响。三个维度的差异在0.34%至1.54%之间。
在从主模型上取下印模的10分钟内,本研究结果表明,四种市售消毒剂不会影响不可逆水胶体或P.V.S.的尺寸稳定性。应进一步开展研究,以阐明这些喷雾形式的溶液对不可逆水胶体和P.V.S.印模表面的抗菌效果。