Department of Orthodontics, Faculty of Dental Medicine, University of Rijeka, Rijeka, Croatia.
Department of Orthodontics, Clinic for Dental Medicine, Clinical Hospital Centre Rijeka, Rijeka, Croatia.
Cent Eur J Public Health. 2022 Sep;30(3):173-178. doi: 10.21101/cejph.a7122.
This study aimed to assess the predictors of allergic sensitisation to titanium and nickel in patients undergoing orthodontic treatment.
A total of 250 patients undergoing orthodontic treatment were invited to participate, and 235 were analysed (67% females). A patch test was performed using nickel sulphate, titanium, titanium dioxide, titanium oxalate, titanium nitride, and petrolatum as control. In addition, clinical signs of the oral mucosa, gingiva, tongue, lips, and allergological history were assessed.
The predictors of metal allergic sensitisation in patients undergoing orthodontic treatment were adult age (OR = 2.6; 95% CI: 1.2-5.5; p = 0.016), female sex (OR = 3.0; 95% CI: 1.1-7.9; p = 0.025), exfoliative cheilitis (OR = 4.8; 95% CI: 1.9-12.4; p = 0.001), history of contact hypersensitivity (OR = 7.0; 95% CI: 1.3-35.4; p = 0.025), history of contact hypersensitivity to metals (OR = 8.3; 95% CI: 1.4-50.2; p = 0.021), and piercings (OR = 5.4; 95% CI: 2.1-13.9; p = 0.001). When predictors were analysed separately for these two metals, titanium sensitisation predictors were contact hypersensitivity to metals and piercing, whereas nickel sensitisation predictors were age and piercing.
A positive patch test alone cannot draw definite conclusions regarding allergy. However, metal allergies in patients with orthodontic appliances could be considered in cases of previous contact hypersensitivity, previous reactions to metals, exfoliative cheilitis, and piercing.
本研究旨在评估接受正畸治疗的患者对钛和镍过敏的预测因素。
共邀请 250 名接受正畸治疗的患者参加,其中 235 名患者进行了分析(67%为女性)。使用硫酸镍、钛、二氧化钛、草酸钛、氮化钛和凡士林作为对照进行斑贴试验。此外,还评估了口腔黏膜、牙龈、舌、唇的临床体征和过敏病史。
正畸治疗患者金属过敏的预测因素为成年年龄(OR=2.6;95%CI:1.2-5.5;p=0.016)、女性(OR=3.0;95%CI:1.1-7.9;p=0.025)、剥脱性唇炎(OR=4.8;95%CI:1.9-12.4;p=0.001)、接触性超敏反应史(OR=7.0;95%CI:1.3-35.4;p=0.025)、对金属的接触性超敏反应史(OR=8.3;95%CI:1.4-50.2;p=0.021)和穿孔(OR=5.4;95%CI:2.1-13.9;p=0.001)。当分别对这两种金属进行预测因素分析时,钛过敏的预测因素是对金属和穿孔的接触性超敏反应,而镍过敏的预测因素是年龄和穿孔。
单独的斑贴试验阳性不能确定过敏的结论。然而,在有正畸器具的患者中,如果有既往接触性超敏反应、既往对金属的反应、剥脱性唇炎和穿孔,应考虑金属过敏。