Suppr超能文献

一种使用衰减全反射红外光谱法定量测量角质层水浓度的非侵入性体内技术。

A noninvasive, in vivo technique to quantitatively measure water concentration of the stratum corneum using attenuated total-reflectance infrared spectroscopy.

作者信息

Potts R O, Guzek D B, Harris R R, McKie J E

出版信息

Arch Dermatol Res. 1985;277(6):489-95. doi: 10.1007/BF00510068.

Abstract

In order to noninvasively measure water concentration in the stratum corneum, infrared spectra were obtained using an attenuated total-reflectance technique in conjunction with Fourier transform spectroscopy. A weak water-absorbance band near 2,100 cm-1 was detected in both in vivo and in vitro spectra. The significance of this band is that it occurs in a region of the mid-infrared where the stratum corneum and most topically applied substances show no absorbance. In vitro spectra obtained as a function of ambient relative humidity showed an increase in the absorbance near 2,100 cm-1 with increasing water concentration in the stratum corneum. The combined in vivo and in vitro results lead to a quantitative assessment of water concentration in the uppermost layers of the stratum corneum.

摘要

为了无创测量角质层中的水分浓度,采用衰减全反射技术结合傅里叶变换光谱法获取红外光谱。在体内和体外光谱中均检测到了一个位于2100 cm-1附近的弱吸水带。该波段的重要意义在于,它出现在中红外区域,在此区域角质层和大多数局部应用的物质均无吸收。作为环境相对湿度函数获得的体外光谱显示,随着角质层中水分浓度的增加,2100 cm-1附近的吸光度增加。体内和体外结果相结合,实现了对角质层最上层水分浓度的定量评估。