Suppr超能文献

离子钙和可溶性镁对铜绿假单胞菌庆大霉素药敏试验中穆勒-欣顿琼脂性能可预测性的影响。

Effect of ionized calcium and soluble magnesium on the predictability of the performance of Mueller-Hinton agar susceptibility testing of Pseudomonas aeruginosa with gentamicin.

作者信息

Casillas E, Kenny M A, Minshew B H, Schoenknecht F D

出版信息

Antimicrob Agents Chemother. 1981 Jun;19(6):987-92. doi: 10.1128/AAC.19.6.987.

Abstract

The soluble and ionized calcium and magnesium contents of 18 lots of Mueller-Hinton agar medium from three different manufacturers were analyzed, and the results were correlated with medium performance. A standardized disk diffusion test, with Pseudomonas aeruginosa (ATCC 27853) and a 10-microgram gentamicin disk, served as an indicator of medium performance. Zone diameters correlated well with the ionized calcium values and the sum of the ionized calcium and soluble magnesium values in the different lots (r = -0.88 for both). Zone diameters correlated poorly with ionized magnesium values (r = -0.57), which were best described by a curvilinear relationship. Supplementation of lots of Mueller-Hinton agar medium with equivalent amounts of calcium and magnesium as the chloride, gluconate, or glycerophosphate salts produced identical decreases in zone sizes. Adjustment of deficient lots of Mueller-Hinton agar medium with ionized calcium or soluble magnesium or both (as the gluconate salts), to match the concentrations in lots that provided satisfactory zone sizes (17 to 19 mm), resulted in performance comparable to that of the control lots. Sixteen strains of Pseudomonas aeruginosa, ranging from resistant to susceptible, responded to cation adjustment in the same manner as the ATCC quality control strain. Satisfactory medium performance can obviously be assured by biological means in aminoglycoside susceptibility testing of Pseudomonas aeruginosa on Mueller-Hinton medium; however, cation adjustment of medium to predetermined levels of ionized calcium and soluble magnesium can now also provide desirable performance levels for P. aeruginosa on Mueller-Hinton medium.

摘要

分析了来自三个不同制造商的18批穆勒-欣顿琼脂培养基的可溶性和离子化钙、镁含量,并将结果与培养基性能相关联。使用铜绿假单胞菌(ATCC 27853)和10微克庆大霉素纸片进行标准化纸片扩散试验,作为培养基性能的指标。不同批次的抑菌圈直径与离子化钙值以及离子化钙和可溶性镁值之和相关性良好(两者r = -0.88)。抑菌圈直径与离子化镁值相关性较差(r = -0.57),离子化镁值最好用曲线关系来描述。向多批穆勒-欣顿琼脂培养基中添加等量的钙和镁,以氯化物、葡萄糖酸盐或甘油磷酸盐形式存在,会使抑菌圈大小出现相同程度的减小。用离子化钙或可溶性镁或两者(以葡萄糖酸盐形式)调整不足的穆勒-欣顿琼脂培养基批次,使其浓度与能产生满意抑菌圈大小(17至19毫米)的批次相匹配,结果显示其性能与对照批次相当。16株从耐药到敏感的铜绿假单胞菌菌株,对阳离子调整的反应与ATCC质量控制菌株相同。在穆勒-欣顿培养基上对铜绿假单胞菌进行氨基糖苷类药敏试验时,显然可以通过生物学方法确保培养基性能良好;然而,将培养基的阳离子调整到预定的离子化钙和可溶性镁水平,现在也能为铜绿假单胞菌在穆勒-欣顿培养基上提供理想的性能水平。

相似文献

引用本文的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验