La Scolea L J, Dryja D, Neter E
J Clin Microbiol. 1981 Dec;14(6):661-4. doi: 10.1128/jcm.14.6.661-664.1981.
The efficacy and reproducibility of the quantitative direct plating (QDP) method and the semi-automated BACTEC radiometric system (BBL Microbiology Systems, Cockeysville, Md.) were analyzed for the rapid diagnosis of Haemophilus influenzae bacteremia on the basis of 41 positive cultures from 35 patients. The QDP method detected 61% and BACTEC only 19% of the positive cultures within the first 12 h. Similarly, the QDP procedure yielded growth of H. influenzae in 56% of the cultures before a positive growth index reading was obtained with the BACTEC method. The observation that the quantitative procedure recovered H. influenzae in 88% of all positive cultures, using only 1 ml or less of blood, is attributed to the fact that 68% of the cultures had counts in excess of 100 colony-forming units per ml. The reproducibility of the QDP method was documented by the fact that duplicate blood cultures taken within a few hours of each other yielded comparable results on the number of bacteria at low (1 to 100/ml), moderate (100 to 1,000/ml), and high (greater than 1,000/ml) levels of bacteremia. We concluded that the QDP method is a valuable, simple, and inexpensive supplementary technique to the semi-automated BACTEC procedure for the rapid diagnosis of H.influenzae bacteremia in children.
基于35例患者的41份阳性培养物,分析了定量直接接种(QDP)方法和半自动BACTEC放射测量系统(BBL微生物系统公司,马里兰州科基斯维尔)在快速诊断流感嗜血杆菌菌血症方面的有效性和可重复性。QDP方法在前12小时内检测出61%的阳性培养物,而BACTEC仅检测出19%。同样,在BACTEC方法获得阳性生长指数读数之前,QDP程序在56%的培养物中培养出了流感嗜血杆菌。定量程序仅使用1毫升或更少的血液,就在88%的所有阳性培养物中培养出了流感嗜血杆菌,这一观察结果归因于68%的培养物每毫升的菌落形成单位数超过100。QDP方法的可重复性体现在以下事实上:在几小时内采集的两份重复血培养物,对于低(1至100/毫升)、中(100至1000/毫升)和高(大于1000/毫升)菌血症水平的细菌数量产生了可比的结果。我们得出结论,对于儿童流感嗜血杆菌菌血症的快速诊断,QDP方法是半自动BACTEC程序的一种有价值、简单且廉价的补充技术。