Suppr超能文献

用于检测菌血症的辐射测量系统的评估

Evaluation of radiometric system for detecting bacteremia.

作者信息

Renner E D, Gatheridge L A, Washington J A

出版信息

Appl Microbiol. 1973 Sep;26(3):368-72. doi: 10.1128/am.26.3.368-372.1973.

Abstract

An automated radiometric system (BACTEC, Johnston Laboratories) for detection of bacteremia was evaluated in parallel with a standard blood culture system in use in our laboratory. Of 1,445 blood cultures from 484 patients with possible bacteremia, 106 sets of cultures (excluding 39 presumed contaminated), representing 56 patients, were positive by both methods. The conventional system yielded 85 positive cultures from 48 patients, whereas the BACTEC system yielded 84 positive cultures from 43 patients. The BACTEC system failed to detect 22 cultures that were positive in the conventional system, and the conventional system failed to detect 21 cultures that were positive in the BACTEC system. The detection efficiency was generally equivalent in the two systems except for the lower detection rates of anaerobes and Enterobacter aerogenes by the BACTEC system and the lower detection rates of Torulopsis glabrata and, possibly, Pseudomonas sp. (group IVD) in the conventional system. The BACTEC system had a slight advantage over the conventional system in the time interval to detection of positivity. Approximately 20% of the positive cultures detected by the BACTEC system were detected on the first day of incubation compared with 7% by the conventional system. The recovery rates and detection times of anaerobes were less efficient by the BACTEC system than by the conventional system. It does not appear that the radiometric method has much advantage over available conventional methods.

摘要

我们使用一种自动化放射性测量系统(BACTEC,约翰斯顿实验室)来检测菌血症,并与我们实验室正在使用的标准血培养系统进行了平行评估。在对484例可能患有菌血症的患者进行的1445次血培养中,两种方法均检测出阳性的培养物有106套(不包括39套疑似污染的培养物),涉及56例患者。传统系统从48例患者中检测出85份阳性培养物,而BACTEC系统从43例患者中检测出84份阳性培养物。BACTEC系统未能检测出传统系统中呈阳性的22份培养物,传统系统也未能检测出BACTEC系统中呈阳性的21份培养物。除了BACTEC系统对厌氧菌和产气肠杆菌的检测率较低,以及传统系统对光滑球拟酵母菌和可能的假单胞菌属(IVD组)的检测率较低外,两种系统的检测效率总体相当。在检测阳性的时间间隔方面,BACTEC系统比传统系统略有优势。BACTEC系统检测出的阳性培养物中约20%在培养的第一天就被检测到,而传统系统为7%。BACTEC系统对厌氧菌的回收率和检测时间比传统系统低。放射性测量方法似乎并不比现有的传统方法有太多优势。

相似文献

1
Evaluation of radiometric system for detecting bacteremia.用于检测菌血症的辐射测量系统的评估
Appl Microbiol. 1973 Sep;26(3):368-72. doi: 10.1128/am.26.3.368-372.1973.

引用本文的文献

本文引用的文献

1
Radiometric method for detection of bacteremia.检测菌血症的放射测量法。
Appl Microbiol. 1971 Jul;22(1):100-1. doi: 10.1128/am.22.1.100-101.1971.
4
Automated detection of Haemophilus influenzae.流感嗜血杆菌的自动检测
Appl Microbiol. 1973 Jun;25(6):1011-2. doi: 10.1128/am.25.6.1011-1012.1973.