风疹病毒血凝抑制 IgM 抗体:与密度梯度超速离心法相比,用葡萄球菌蛋白 A 吸收 IgG 的方法(作者译)

[Rubella virus hemagglutination inhibition IgM antibodies: the method of absorption of IgG by staphylococcal protein A as compared with density gradient ultracentrifugation (author's transl)].

作者信息

Roggendorf M, Schneweis K E, Wolff M H

出版信息

Zentralbl Bakteriol Orig A. 1976 Aug;235(4):363-72.

PMID:790852
Abstract

The elimination of IgG by adsorption to Protein A of S. aureus was used for the demonstration of rubella virus specific IgM by hemagglutination inhibition. The validity of the method was proved by comparison with the results of density gradient centrifugation. The adsorption procedure led to false positive results in 9 of 56 cases and to false negative results in 12 of 46 cases, i.e. 20.7% of the results were discordant, when the sera were tested with short incubation time (30 min. room temperature) and the residual IgG (and IgA) were not excluded by controls with 2-ME (table 1 and table 2). By prolonged incubation time (18 hrs + 4 degrees C) and controls with 2-ME, false positive results were avoided, and the number of false negative results was reduced to 9 (table 2 and table 3). The latter occured mostly in cases where the disease had started 3 or more weeks ago and the titer in the IgM fraction of the sera was low (fig. 3). Under these conditions the absorption of IgG by staphylococcal Protein A proved to be a simple, specific and reliable procedure for the demonstration of rubella virus IgM within 2-3 weeks after the onset of the disease.

摘要

通过将IgG吸附到金黄色葡萄球菌的蛋白A上以去除IgG,从而采用血凝抑制法检测风疹病毒特异性IgM。通过与密度梯度离心结果进行比较,证明了该方法的有效性。当血清在短孵育时间(室温30分钟)下进行检测且未用2-巯基乙醇(2-ME)对照排除残留的IgG(和IgA)时,吸附过程在56例中有9例产生假阳性结果,在46例中有12例产生假阴性结果,即20.7%的结果不一致(表1和表)。通过延长孵育时间(18小时+4℃)并用2-ME进行对照,可避免假阳性结果,且假阴性结果的数量减少至9例(表2和表3)。后者大多发生在疾病开始3周或更长时间前且血清IgM部分滴度较低的病例中(图3)。在这些条件下,葡萄球菌蛋白A对IgG的吸附被证明是一种在疾病发作后2至3周内检测风疹病毒IgM的简单、特异且可靠的方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验