Suppr超能文献

使用碘海醇的单次注射法评估猫和狗的肾小球滤过率。

Evaluation of a single injection method, using iohexol, for estimating glomerular filtration rate in cats and dogs.

作者信息

Brown S A, Finco D R, Boudinot F D, Wright J, Taver S L, Cooper T

机构信息

Department of Physiology and Pharmacology, University of Georgia, Athens 20602, USA.

出版信息

Am J Vet Res. 1996 Jan;57(1):105-10.

PMID:8720247
Abstract

OBJECTIVE

To evaluate the utility of a method for estimating glomerular filtration rate (GFR) after single IV administration of iohexol.

DESIGN

The plasma clearance of iodine (PCI), taken as the quotient of the administered dose of iodine (300 to 600 mg of l/kg of body weight) divided by the area under the plasma iodine concentration versus time curve determined by 4 methods (PCI1-PCI4). The results for PCI were compared with simultaneously obtained values for the urinary clearance of exogenously administered creatinine (CCr), a widely accepted method for the measurement of GFR in cats and dogs.

ANIMALS

Cats and dogs that were renal intact (n = 5 cats; n = 1 dog) or had renal mass reduced by partial nephrectomy (n = 5 cats; n = 7 dogs).

RESULTS

Values for PCI were closely related (R2 values ranged from 0.947 to 0.992; P < 0.0001 in all cases) to CCr. Despite this close correlation between CCr and PCI, the 95% confidence interval for the difference between PCI3 and CCr included values that exceeded 1.4 ml/min/kg, which represents 50% of the mean value for CCr in renal-intact cats.

CONCLUSIONS

Determination of PCI provided a reliable estimate of GFR in cats and dogs of this study. However, differences between 1 of the methods (PCI3) and CCr are clinically important, emphasizing the need to use more than simple linear regression analysis and correlation coefficients when attempting to validate new measurement techniques.

CLINICAL RELEVANCE

The determination of PCI provided a reliable estimate of GFR in cats and dogs of this study.

摘要

目的

评估单次静脉注射碘海醇后估算肾小球滤过率(GFR)方法的实用性。

设计

以碘的血浆清除率(PCI)作为碘给药剂量(300至600mg碘/千克体重)除以通过4种方法(PCI1 - PCI4)确定的血浆碘浓度-时间曲线下面积的商。将PCI结果与同时获得的外源性肌酐尿清除率(CCr)值进行比较,CCr是猫和狗中广泛接受的测量GFR的方法。

动物

肾脏功能正常的猫和狗(5只猫;1只狗)或经部分肾切除使肾质量减少的猫和狗(5只猫;7只狗)。

结果

PCI值与CCr密切相关(R²值范围为0.947至0.992;所有情况下P < 0.0001)。尽管CCr和PCI之间存在密切相关性,但PCI3与CCr之间差异的95%置信区间包含超过1.4ml/min/kg的值,这代表了肾脏功能正常猫中CCr平均值的50%。

结论

本研究中猫和狗的PCI测定提供了GFR的可靠估计。然而,其中一种方法(PCI3)与CCr之间的差异具有临床重要性,强调在试图验证新测量技术时,需要使用不仅仅是简单的线性回归分析和相关系数。

临床相关性

本研究中猫和狗的PCI测定提供了GFR的可靠估计。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验