Balfour A H, Harford J P
J Clin Pathol. 1985 Jun;38(6):679-89. doi: 10.1136/jcp.38.6.679.
A total of 138 serum samples submitted for toxoplasma serology have been examined by enzyme immunoassay using kits produced by Labsystems Oy for the detection of specific antibodies of the IgG and IgM class. Results were compared with the dye test, an indirect haemagglutination test, and an indirect immunofluorescence test for specific IgM. The enzyme immunoassay was less sensitive than the dye test, but by running both IgG and IgM enzyme immunoassays, 92.4% sensitivity was achieved. The specificity of the enzyme immunoassay was good, with only one dye test negative serum giving a positive (but weak) IgG enzyme immunoassay reaction. Thirty serum samples from patients with no evidence of exposure to Toxoplasma gondii gave negative results in the IgM enzyme immunoassay. Enzyme immunoassay results were expressed in enzyme immunoassay units, as a percentage value of a standard serum. This convention will be of value in the direct comparison of assay systems and in the application of quality control procedures.
共有138份提交用于弓形虫血清学检测的血清样本,采用Labsystems Oy公司生产的试剂盒,通过酶免疫测定法检测IgG和IgM类特异性抗体。将结果与染色试验、间接血凝试验以及针对特异性IgM的间接免疫荧光试验进行比较。酶免疫测定法的敏感性低于染色试验,但同时进行IgG和IgM酶免疫测定时,敏感性达到了92.4%。酶免疫测定法的特异性良好,仅有一份染色试验阴性的血清在IgG酶免疫测定中出现阳性(但较弱)反应。30份无弓形虫暴露证据患者的血清样本在IgM酶免疫测定中结果为阴性。酶免疫测定结果以酶免疫测定单位表示,作为标准血清的百分比值。这种惯例对于检测系统的直接比较以及质量控制程序的应用具有价值。