Suppr超能文献

经食管二维超声心动图和彩色多普勒血流速度图在心脏瓣膜假体评估中的应用

Transesophageal two-dimensional echocardiography and color Doppler flow velocity mapping in the evaluation of cardiac valve prostheses.

作者信息

Nellessen U, Schnittger I, Appleton C P, Masuyama T, Bolger A, Fischell T A, Tye T, Popp R L

机构信息

Division of Cardiology, Stanford University School of Medicine, California 94305.

出版信息

Circulation. 1988 Oct;78(4):848-55. doi: 10.1161/01.cir.78.4.848.

Abstract

To determine the value of transesophageal ultrasound in the assessment of cardiac valve prostheses, 14 patients with clinically suspected mitral prosthesis malfunction were studied by transthoracic and transesophageal two-dimensional imaging as well as by color Doppler flow velocity mapping (color Doppler). Patients underwent left ventricular angiography (n = 13), surgery (n = 11), or both angiography and surgery (n = 10). Nine patients had only mitral valve replacement, four patients had both mitral and aortic valve replacement, and one patient had mitral, aortic, and tricuspid valve replacement. There were 16 biological and four mechanical prostheses. The degree of mitral regurgitation was graded by both transthoracic and transesophageal color Doppler according to the area of the regurgitant jet visualized and was compared with a three-point classification of mitral regurgitation by left ventricular angiography judged by observers blinded to the echocardiographic results. All transesophageal studies were performed without complication and were well tolerated. The pathological morphology of the mitral prosthesis was additionally or more clearly visualized by transesophageal two-dimensional imaging and subsequently proven at surgery in three patients with flail leaflets and one patient with a vegetation compared with images obtained by the transthoracic approach. Valvular regurgitation was graded by the transthoracic approach as absent in four patients, mild in two patients, moderate in five patients, and severe in only three patients. The transesophageal assessment showed absence of mitral regurgitation in two patients, moderate regurgitation in two patients, and severe regurgitation in 10 patients.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

为了确定经食管超声心动图在评估心脏瓣膜假体中的价值,对14例临床怀疑二尖瓣假体功能障碍的患者进行了经胸和经食管二维成像以及彩色多普勒流速图(彩色多普勒)研究。患者接受了左心室血管造影(n = 13)、手术(n = 11)或血管造影和手术(n = 10)。9例患者仅进行了二尖瓣置换,4例患者同时进行了二尖瓣和主动脉瓣置换,1例患者进行了二尖瓣、主动脉瓣和三尖瓣置换。有16个生物假体和4个机械假体。经胸和经食管彩色多普勒根据反流束可视化区域对二尖瓣反流程度进行分级,并与由对超声心动图结果不知情的观察者判断的左心室血管造影二尖瓣反流三点分类法进行比较。所有经食管检查均无并发症,耐受性良好。与经胸检查获得的图像相比,经食管二维成像额外或更清晰地显示了3例连枷瓣叶患者和1例赘生物患者二尖瓣假体的病理形态,随后在手术中得到证实。经胸检查将瓣膜反流分级为:4例患者无反流,2例患者轻度反流,5例患者中度反流,仅3例患者重度反流。经食管评估显示,2例患者无二尖瓣反流,2例患者中度反流,10例患者重度反流。(摘要截选至250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验