IOLMaster 700 与 OA-2000 在年轻健康眼中测量眼生物参数的一致性。

Agreement of ocular biometric measurements in young healthy eyes between IOLMaster 700 and OA-2000.

机构信息

Department of Ophthalmology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China.

Department of Ophthalmology and Optometry, North Sichuan Medical College, Nanchong, China.

出版信息

Sci Rep. 2020 Feb 21;10(1):3134. doi: 10.1038/s41598-020-59919-y.

Abstract

This prospective cross-sectional study aimed to evaluate the agreement of two new biometers for measuring ocular biometric parameters in young healthy eyes. Ocular biometric parameters were measured using IOLMaster 700 and OA-2000. Power vector analyses of Cartesian (J0) and oblique (J45) components of corneal astigmatism were performed. The right eyes of 103 healthy volunteers were analyzed. The 95% limits of agreement ranged from -0.03 to 0.03 mm, -0.08 to 0.07 mm, -0.18 to 0.18 diopters (D), -1.09 to 1.16 D, -1.18 to 1.15 D for axial length (AL), anterior chamber depth (ACD), mean keratometry, J0 and J45 respectively, which were all comparable between the two biometers, while significant differences were detected in lens thickness (LT), central corneal thickness (CCT), white-to-white (WTW) and pupil diameter (PD). Predicted intraocular lens (IOL) powers were comparable between the two biometers by Haigis and Barrett Universal II formulas, while not by SRK/T, Hoffer Q and Holladay 2. Excepting CCT, WTW and PD meaurements, IOLMaster 700 and OA-2000 have excellent agreement on ocular biometric measurements and astigmatism power vectors, which provides more options for ocular biometric measurements and enables constant optimization for IOL power calculation.

摘要

本前瞻性横断面研究旨在评估两种新的生物测量仪在测量年轻健康眼的眼生物测量参数方面的一致性。使用 IOLMaster 700 和 OA-2000 测量眼生物测量参数。对角膜散光的笛卡尔(J0)和斜角(J45)分量的功率向量进行分析。分析了 103 名健康志愿者的右眼。95%的一致性范围为-0.03 至 0.03 毫米、-0.08 至 0.07 毫米、-0.18 至 0.18 屈光度(D)、-1.09 至 1.16 D、-1.18 至 1.15 D 眼轴(AL)、前房深度(ACD)、平均角膜曲率、J0 和 J45,这两种生物测量仪之间均无显著差异,而晶状体厚度(LT)、中央角膜厚度(CCT)、白到白(WTW)和瞳孔直径(PD)则有显著差异。两种生物测量仪的 Haigis 和 Barrett Universal II 公式预测的人工晶状体(IOL)屈光度相当,而 SRK/T、Hoffer Q 和 Holladay 2 公式则不然。除 CCT、WTW 和 PD 测量外,IOLMaster 700 和 OA-2000 在眼生物测量和散光功率向量方面具有极好的一致性,这为眼生物测量提供了更多选择,并使 IOL 功率计算不断得到优化。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f687/7035253/802b8195a7de/41598_2020_59919_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验