Weinstein M P, Reller L B, Mirrett S, Stratton C W, Reimer L G, Wang W L
J Clin Microbiol. 1986 Feb;23(2):221-5. doi: 10.1128/jcm.23.2.221-225.1986.
A commercially available agar-slide blood culture bottle (Septi-Chek; Roche Diagnostics, Div. Hoffman-La Roche, Inc., Nutley, N.J.) was compared with the radiometric blood culture system (BACTEC; Johnston Laboratories, Inc., Towson, Md.) in 8,544 paired blood cultures from adult patients. The systems were inoculated with equal volumes (10 ml) of blood. Overall, there was no statistically significant difference between the two systems in the recovery of clinically important microorganisms, but significantly more members of the family Enterobacteriaceae other than Escherichia coli were detected by the agar-slide system (P less than 0.005). The agar-slide system detected more fungi, and the BACTEC detected more anaerobic bacteria; however, small numbers of recovered organisms precluded statistical significance. When microorganisms grew in both systems, their presence was detected one or more days earlier in the BACTEC (P less than 0.001). More contaminants grew in the agar-slide system (P less than 0.001). Both systems performed well, and either system should provide high yield and prompt detection of positive blood cultures in patients with bacteremia and fungemia if used in an optimal way as recommended by the respective manufacturers.
将市售琼脂平板血培养瓶(Septi-Chek;罗氏诊断公司,霍夫曼-拉罗什公司分部,新泽西州纽特利)与放射性测量血培养系统(BACTEC;约翰斯顿实验室公司,马里兰州陶森),对来自成年患者的8544对血培养样本进行了比较。两个系统均接种等量(10毫升)血液。总体而言,在临床重要微生物的检出方面,两个系统之间无统计学显著差异,但琼脂平板系统检测出的除大肠杆菌外的肠杆菌科菌显著更多(P<0.005)。琼脂平板系统检测出的真菌更多,BACTEC检测出的厌氧菌更多;然而,回收的微生物数量较少,无统计学显著性。当微生物在两个系统中均生长时,BACTEC能比琼脂平板系统提前一天或多天检测到其存在(P<0.001)。琼脂平板系统中生长的污染物更多(P<0.001)。两个系统表现均良好,如果按照各自制造商推荐的最佳方式使用,任一系统都应能高效且快速地检测出血液中存在的细菌和真菌。