Thirty-nine electronics workers were investigated by bronchial provocation testing to soldering fluxes containing colophony and were followed up one to four years later. At presentation and on follow-up each worker had nonspecific bronchial reactivity measured with inhaled histamine, and also had detailed measurements of lung function and estimation of total immunoglobulin levels. They completed a questionnaire designed to detect residual disability. The workers were divided into three groups. Twenty had left work after their initial diagnosis, eight had been moved to alternative work within their original factories, and 11 were thought to have asthma unrelated to colophony exposure as they failed to react to colophony at presentation. Histamine reactivity had returned to normal in half the workers who had left their original factories, but in only one worker who had moved within her original factory. This suggested that the nonspecific bronchial reactivity to histamine was the result rather than the cause of the occupational asthma, and that indirect exposure at work was sufficient to delay recovery of histamine reactivity. However, only two of the 20 affected workers who had left their original factories were symptom free on follow-up, and most had a considerable reduction in their quality of life by continuing asthma, which was particularly provoked by exercise, respiratory infections, and nonspecific irritants. Continuing symptoms may have been caused by domestic sources of colophony, or possibly the failure to eliminate colophony from the lungs.

摘要

对39名接触含有松香的焊接助焊剂的电子工人进行了支气管激发试验,并在1至4年后进行了随访。在初次就诊和随访时,对每名工人用吸入组胺法测量了非特异性支气管反应性,还对肺功能进行了详细测量,并估算了总免疫球蛋白水平。他们完成了一份旨在检测残留残疾的问卷。这些工人被分为三组。20人在初次诊断后离职,8人被调至原工厂内的其他工作岗位,11人因初次就诊时对松香无反应而被认为患有与接触松香无关的哮喘。在离开原工厂的工人中,一半人的组胺反应性已恢复正常,但在原工厂内调动工作的工人中只有1人恢复正常。这表明对组胺的非特异性支气管反应性是职业性哮喘的结果而非原因,并且工作中的间接接触足以延迟组胺反应性的恢复。然而,在离开原工厂的20名受影响工人中,只有2人在随访时无症状,并且大多数人因持续性哮喘导致生活质量大幅下降,运动、呼吸道感染和非特异性刺激物尤其会诱发哮喘。持续的症状可能是由家庭来源的松香引起的,也可能是肺部未能清除松香所致。

相似文献

3
Bronchial provocation studies in workers exposed to the fumes of electronic soldering fluxes.
Clin Allergy. 1980 Mar;10(2):137-49. doi: 10.1111/j.1365-2222.1980.tb02091.x.
4
Occupational asthma in an electronics factory.
Thorax. 1979 Feb;34(1):13-8. doi: 10.1136/thx.34.1.13.
5
Peak flow rate records in the diagnosis of occupational asthma due to colophony.
Thorax. 1979 Jun;34(3):308-16. doi: 10.1136/thx.34.3.308.
6
Occupational asthma in a factory making flux-cored solder containing colophony.
Thorax. 1981 Nov;36(11):828-34. doi: 10.1136/thx.36.11.828.
8
Respiratory disease in workers exposed to colophony solder flux fumes: continuing health concerns.
Occup Med (Lond). 1997 Nov;47(8):491-6. doi: 10.1093/occmed/47.8.491.
10
Adverse effects of colophony.
Ind Health. 1997;35(1):1-7. doi: 10.2486/indhealth.35.1.

引用本文的文献

1
Workplace interventions for treatment of occupational asthma.
Cochrane Database Syst Rev. 2019 Oct 8;10(10):CD006308. doi: 10.1002/14651858.CD006308.pub4.
2
Diagnostic approach in cases with suspected work-related asthma.
J Occup Med Toxicol. 2013 Jun 14;8(1):17. doi: 10.1186/1745-6673-8-17.
3
What is the optimal management option for occupational asthma?
Eur Respir Rev. 2012 Jun 1;21(124):97-104. doi: 10.1183/09059180.00004911.
4
Work-related respiratory symptoms and lung function among solderers in the electronics industry: a meta-analysis.
Environ Health Prev Med. 2012 May;17(3):183-90. doi: 10.1007/s12199-011-0236-8. Epub 2011 Aug 31.
5
Outcome of occupational asthma after cessation of exposure: a systematic review.
Thorax. 2007 Feb;62(2):147-52. doi: 10.1136/thx.2006.061952. Epub 2006 Oct 13.
6
Evidence based guidelines for the prevention, identification, and management of occupational asthma.
Occup Environ Med. 2005 May;62(5):290-9. doi: 10.1136/oem.2004.016287.
7
Health, employment, and financial outcomes in workers with occupational asthma.
Br J Ind Med. 1993 Jun;50(6):491-6. doi: 10.1136/oem.50.6.491.
8
Reported incidence of occupational asthma in the United Kingdom, 1989-90.
J Epidemiol Community Health. 1993 Dec;47(6):459-63. doi: 10.1136/jech.47.6.459.
9
Occupational lung disease induced by reactive chemicals.
Clin Rev Allergy. 1985 May;3(2):217-26. doi: 10.1007/BF02992984.
10
Occupational asthma in workers of a pharmaceutical company processing spiramycin.
Thorax. 1988 May;43(5):371-7. doi: 10.1136/thx.43.5.371.

本文引用的文献

1
Bronchial provocation studies in workers exposed to the fumes of electronic soldering fluxes.
Clin Allergy. 1980 Mar;10(2):137-49. doi: 10.1111/j.1365-2222.1980.tb02091.x.
2
Occupational asthma in a factory making flux-cored solder containing colophony.
Thorax. 1981 Nov;36(11):828-34. doi: 10.1136/thx.36.11.828.
3
The relationship between bronchial histamine reactivity and atopic status.
Clin Allergy. 1976 Jul;6(4):373-81. doi: 10.1111/j.1365-2222.1976.tb01919.x.
6
Nonspecific bronchial reactivity in occupational asthma.
J Allergy Clin Immunol. 1979 Jan;63(1):28-34. doi: 10.1016/0091-6749(79)90158-1.
8
Occupational asthma in an electronics factory.
Thorax. 1979 Feb;34(1):13-8. doi: 10.1136/thx.34.1.13.
9
Respiratory disease in workers exposed to solder flux fumes containing colophony (pine resin).
Clin Allergy. 1978 Jan;8(1):1-14. doi: 10.1111/j.1365-2222.1978.tb00441.x.
10

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验