An indirect solid-phase radioimmunoassay (RIA) has been developed for the detection of immunoglobulin (Ig) class-specific rubella antibodies. A commercial rubella haemagglutinin is dried and fixed on to the wells of flexible microtitre plates and allowed to react with serial dilutions of whole or fractionated human sera. Class-specific rubella antibodies are then detected by determining the specific binding of 125I-labelled anti-human IgG or IgM. The RIA was first evaluated by comparison with the haemagglutination-inhibition (HI) test for the detection of rubella-specific IgM in gel-filtration fractions. RIA was found to be as specific as HI but 10-150 times more sensitive. Rubella-specific IgG antibodies did not interfere in specific IgM determinations by RIA and therefore the latter technique was applied to unfractionated sera. The results obtained indicate that RIA on unfractionated sera is a practical, sensitive and specific technique which could provide a reliable method for the diagnosis of rubella. The rubella-specific IgM titres obtained by RIA were not increased by the removal of IgG by pretreatment of sera with Staphylococcal Protein A.

摘要

已开发出一种间接固相放射免疫测定法(RIA)用于检测免疫球蛋白(Ig)类特异性风疹抗体。将一种商业风疹血凝素干燥并固定在柔性微量滴定板的孔中,使其与全份或分级分离的人血清系列稀释液反应。然后通过测定125I标记的抗人IgG或IgM的特异性结合来检测类特异性风疹抗体。首先通过与血凝抑制(HI)试验比较,对RIA进行评估,以检测凝胶过滤级分中的风疹特异性IgM。发现RIA与HI一样特异,但灵敏度高10 - 150倍。风疹特异性IgG抗体不干扰RIA对特异性IgM的测定,因此后一种技术应用于未分级的血清。所得结果表明,对未分级血清进行RIA是一种实用、灵敏且特异的技术,可为风疹诊断提供可靠方法。用葡萄球菌蛋白A预处理血清以去除IgG,并不会提高通过RIA获得的风疹特异性IgM滴度。

相似文献

引用本文的文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验