对比 IOLMaster 500 和 IOLMaster 700 在白内障患者眼生物测量参数测量中的应用。

A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients.

机构信息

Department of Ophthalmology, Qingdao Eye Hospital of Shandong First Medical University, Shandong Eye Institute, Shandong Provincial Key Laboratory of Ophthalmology-State Key Laboratory Cultivation Base, Qingdao, 266000, Shandong, China.

Department of Urology, Qingdao Municipal Hospital Affiliated to Qingdao University, 1 Jiaozhou Road, Qingdao, 266011, Shandong, China.

出版信息

Sci Rep. 2022 Jul 27;12(1):12770. doi: 10.1038/s41598-022-16985-8.

Abstract

To compare the agreement of ocular biometric parameters measured by IOLMaster 500 and IOLMaster 700. This is a prospective study. IOLMaster 500 and IOLMaster 700 were used to measure the axial eye length (AL), corneal flat keratometry (Kf), corneal steep keratometry (Ks), mean keratometry (Km), corneal astigmatism(CA), J0, J45, anterior chamber depth (ACD) and corneal horizontal diameter (white-to-white distance, WTW) of 518 eyes (392 patients) with cataracts. Patients were enrolled unilaterally. Subgroup analyses were done according to the AL and Km. The intraclass correlation coefficient (ICC) and Bland-Altman analysis were used to evaluate the agreement. A total of 275 eyes were analyzed. The 95% confidence interval of ICC of the mean AL, Ks, Kf, Km, J0, and ACD values measured by the two instruments are indicative of excellent reliability (P < 0.001). The measurement results of WTW show good reliability (P < 0.001). The ICC of CA is of good reliability in CA < 0.5 D group (P = 0.000) and moderate reliability in the other two groups (P = 0.000). The WTW is the widest range among 95% consistency of the limit range measured by the two instruments. The results of IOLMaster 500 and IOLMaster 700 in measuring AL, keratometry, and ACD in cataract patients are of high agreement.

摘要

比较 IOLMaster 500 和 IOLMaster 700 测量的眼生物测量参数的一致性。这是一项前瞻性研究。使用 IOLMaster 500 和 IOLMaster 700 测量 392 例(518 只眼)白内障患者的眼轴(AL)、角膜平 K 值(Kf)、角膜陡 K 值(Ks)、平均 K 值(Km)、角膜散光(CA)、J0、J45、前房深度(ACD)和角膜水平直径(白对白距离,WTW)。患者单侧入组。根据 AL 和 Km 进行亚组分析。采用组内相关系数(ICC)和 Bland-Altman 分析评估一致性。共分析了 275 只眼。两种仪器测量的平均 AL、Ks、Kf、Km、J0 和 ACD 值的 ICC 的 95%置信区间表明可靠性极佳(P<0.001)。WTW 的测量结果具有良好的可靠性(P<0.001)。CA 的 ICC 在 CA<0.5 D 组具有良好的可靠性(P=0.000),在其他两组具有中度可靠性(P=0.000)。在两种仪器测量的 95%一致性限值范围内,WTW 的范围最宽。两种仪器在测量白内障患者的 AL、角膜曲率和 ACD 方面具有高度一致性。