Suppr超能文献

用于厌氧细菌鉴定的Minitek小型化鉴别系统的改良

Modification of the Minitek Miniaturized Differentiation System for characterization of anaerobic bacteria.

作者信息

Stargel D, Thompson F S, Phillips S E, Lombard G L, Dowell V R

出版信息

J Clin Microbiol. 1976 Mar;3(3):291-301. doi: 10.1128/jcm.3.3.291-301.1976.

Abstract

The Minitek Miniaturized System (BBL) was modified for characterization of anaerobic bacteria. The modified system and the conventional Center for Disease Control method were used to test a variety of anaerobic bacteria, and results were compared. Tests performed by both techniques were indole and H2S production, esculin hydrolysis, nitrate reduction, and fermentation of glucose, mannitol, lactose, sucrose, maltose, salicin, glycerol, xylose, arabinose, mannose, rhamnose, and trehalose. The manufacturer's recommended procedure for the Minitek system was modified by using a new suspension medium (Lombard-Dowell broth) and an inoculum equivalent to the density of a McFarland no. 5 nephelometer standard. The Minitek results, recorded after 48 h, agreed satisfactorily with the conventional test results, usually recorded after 5 to 7 days of incubation. In the examination of 80 strains representing 22 different species or subspecies of anaerobic bacteria, with 16 biochemical tests performed in triplicate, 93.8% of the Minitek test results agreed with those of the corresponding conventional tests. Only tests for indole, H2S, and nitrate reduction gave less than 90% agreement. It was concluded that the modified Minitek system is a suitable substitute for the more expensive and time-consuming conventional procedure for determining carbohydrate fermentation and esculin hydrolysis by anaerobes. This system, when used in conjunction with other tests, can effectively aid in the definitive identification of commonly isolated anaerobes.

摘要

对Minitek小型化系统(BBL)进行了改进,以用于厌氧细菌的鉴定。使用改进后的系统和传统的疾病控制中心方法对多种厌氧细菌进行检测,并比较结果。两种技术所进行的检测包括吲哚和硫化氢产生、七叶苷水解、硝酸盐还原以及葡萄糖、甘露醇、乳糖、蔗糖、麦芽糖、水杨苷、甘油、木糖、阿拉伯糖、甘露糖、鼠李糖和海藻糖的发酵。通过使用一种新的悬浮培养基(Lombard-Dowell肉汤)和相当于麦氏5号比浊标准密度的接种物,对Minitek系统制造商推荐的程序进行了修改。48小时后记录的Minitek结果与通常在培养5至7天后记录的传统检测结果令人满意地一致。在对代表22种不同厌氧细菌物种或亚种的80株菌株进行检测时,对16项生化试验进行了三次重复,Minitek检测结果中有93.8%与相应的传统检测结果一致。只有吲哚、硫化氢和硝酸盐还原检测的一致性低于90%。得出的结论是,改进后的Minitek系统是一种合适的替代方法,可替代用于确定厌氧菌碳水化合物发酵和七叶苷水解的更昂贵且耗时的传统程序。该系统与其他检测方法结合使用时,可有效辅助对常见分离厌氧菌进行明确鉴定。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6af7/274286/deba0156d7ed/jcm00224-0098-a.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验