Suppr超能文献

日本健康年轻大学生眼球前段屈光不正和生物测量学。

Refractive error and biometrics of anterior segment of eyes of healthy young university students in Japan.

机构信息

Department of Ophthalmology, Mie University School of Medicine, Tsu, Japan.

Department of Ophthalmology, Bantane Hospital, School of Medicine, Fujita Health University, Nagoya, Japan.

出版信息

Sci Rep. 2019 Oct 25;9(1):15337. doi: 10.1038/s41598-019-51920-4.

Abstract

To determine the parameters of the anterior segment of eyes that are significantly associated with the refractive error in healthy young Japanese university students. This was a cross-sectional observational study of 229 healthy Japanese university students (men: women,147:82) whose age ranged between 20 to 29 years. Univariate and multivariate linear regression analyses were performed to identify the factors that were significantly correlated with the refractive error. The independent variables included age, sex, axial length, anterior chamber depth, corneal diameter, curvature of anterior surface of cornea, and central corneal thickness. The mean refractive error (spherical equivalent) was -4.1 ± 2.7 diopters (D) with a range of -12.5 to +0.5 D, and the mean axial length was 25.4 ± 1.3 mm with a range of 22.4 to 29.0 mm. Pearson univariate correlation analysis found that the refractive error was significantly and negatively correlated with the axial length (R = -0.82, P < 0.001), deeper anterior chamber (R = -0.30, P < 0.001), and larger corneal diameter (R = -0.21, P = 0.001). Multiple regression analysis showed that the refractive error was significantly associated with a longer axial length (P < 0.001), a deeper anterior chamber (P < 0.001), and a flatter corneal curvature (P < 0.001).The biometric values of the anterior segment of the eyes should make the eye more hyperopic which would reduce the myopia-inducing lengthening of the axial length.

摘要

目的

确定与健康年轻日本大学生屈光不正显著相关的眼前节参数。

方法

这是一项横断面观察性研究,共纳入 229 名年龄在 20 至 29 岁之间的健康日本大学生(男:女,147:82)。对年龄、性别、眼轴长度、前房深度、角膜直径、角膜前表面曲率和中央角膜厚度等参数与屈光不正的相关性进行单因素和多因素线性回归分析。

结果

平均屈光度(等效球镜)为-4.1±2.7 屈光度(D),范围为-12.5 至+0.5 D,平均眼轴长度为 25.4±1.3 mm,范围为 22.4 至 29.0 mm。Pearson 单因素相关分析发现,屈光不正与眼轴长度(R=-0.82,P<0.001)、前房深度更深(R=-0.30,P<0.001)和角膜直径更大(R=-0.21,P=0.001)呈显著负相关。多元回归分析显示,屈光不正与眼轴长度较长(P<0.001)、前房深度较深(P<0.001)和角膜曲率更平坦(P<0.001)显著相关。

结论

眼前节的生物测量值可能会使眼睛更加远视,从而减少眼轴长度的近视诱导增长。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/70e0/6814799/e01401359cbc/41598_2019_51920_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验